The Thermo Scientific Eutech 1710 is a pH / mV / temperature bench meter for pH and redox measurements from the Eutech 1700 Series. This configuration (cat. no. EBPH171003) comes with: gel-filled plastic-body double junction pH electrode, ATC probe, solutions, stand, PC cable and power adapter. 3-year warranty against manufacturing defects.
Prices are given by quotation. Add this to your quote cart to request one.
| Cat. no. | EBPH171003 |
|---|---|
| Series | Eutech 1700 Series bench meter |
| Parameters | pH / mV / temperature |
| Supplied with | Gel-filled plastic-body double junction pH electrode, ATC probe, solutions, stand, PC cable and power adapter |
| pH range | -2.00 to 18.00 pH |
| pH resolution | 0.1 / 0.01 pH |
| pH accuracy | ±0.01 pH ±1 LSD |
| pH calibration | 1 to 5 points |
| Automatic buffer sets | USA (1.68, 4.01, 7.00, 10.01, 12.45); NIST (1.68, 4.01, 6.86, 9.18, 12.45) |
| mV / RmV range | ±2000.0 mV |
| mV resolution | 0.1 mV |
| mV accuracy | ±0.2 mV or ±0.05 % of reading, whichever is greater |
| RmV calibration | 1 point |
| Calibration method | Automatic buffer recognition with manual buffer entry option |
| Slope display |
| Yes |
| mV offset adjustment | Up to ±250 mV |
|---|
| Temperature range | -5.0 to 105.0 °C |
|---|
| Temperature resolution | 0.1 °C |
|---|
| Temperature accuracy | ±0.3 °C |
|---|
| Temperature input | Manual or automatic with ATC probe |
|---|
| Temperature calibration | 1 point, ±5.0 °C |
|---|
| Temperature offset adjustment | Up to ±5 °C |
|---|
| Display | 5 in. segmented LCD with backlight |
|---|
| Date and time | Yes |
|---|
| Read types | Continuous, auto-read, timed |
|---|
| Data log | Up to 500 points |
|---|
| Calibration log | pH, RmV and temperature |
|---|
| Data output | Computer or printer |
|---|
| Calibration due alarm | 1 to 168 hours or off |
|---|
| Alarms | Visual and on/off audible |
|---|
| Memory | Non-volatile |
|---|
| Power | 100 to 240 V universal power adapter |
|---|
| Warranty | 3 years |
|---|
| Timed read interval | 5 seconds to 60 minutes |
|---|
| Date format | DD-MM-YYYY or MM-DD-YYYY (selectable); 12-hour time |
|---|
| Sleep mode | Yes, optional |
|---|
| Self-test | Automatic at start-up |
|---|
| Inputs | BNC, ATC |
|---|
| Data output format | CSV or print |
|---|
| Enclosure | IP54 |
|---|
| Certifications | CE, cTUVus, FCC Class B, CES-001, KC, RCM |
|---|
| Power supply | 100 to 240 VAC, 50/60 Hz; 9 V DC adapter, 1.3 A |
|---|
| Dimensions (L × W × H) | 198.3 × 155.2 × 61.7 mm |
|---|
| Weight | 700 g |
|---|
| Operating conditions | Indoors, 5 to 45 °C, 5 to 85 % RH non-condensing, up to 2,000 m altitude |
|---|
| Storage conditions | -20 to 60 °C, 5 to 85 % RH non-condensing |
|---|